Description
Electrohydraulic Actuators
Series 2HX Electrohydraulic Actuators are cylinders engineered for your feedback and control systems. They are offered with bolt-on or integral manifold and/or position sensing devices.
Two Valve Manifold Options: • 7 Standard Bolt-on Manifolds • 4 Standard Integral Manifolds Two Feedback Options: • LDT – Linear Displacement Transducer • LRT – Linear Potentiometer Standard Transducer Specifications • Non-Linearity – Less than ±0.02% of cylinder stroke or ±0.002 inch, whichever is greater. • Repeatability – Better than ±0.001% of cylinder net stroke or 0.001 inch, whichever is greater. • Input Voltage – +13.5 to +26.4 VAC • Standard Operating Temperature – -40° F to 158° F. • Cylinder Stroke Length – Up to 300 inches. • Output – Analog: Voltage or Current, Digital: Start/Stop or PWM